The ELHS load cell is a compact package able to fit into many applications where others cannot. The low noise Wheatstone bridge consists of piezo-resistive strain gages which provide 200 mV of typical full scale output. When compact design, extreme stiffness and superior resolution are required, the ELHS load cell is the sensor for your application. The ELHS is provided with either SAE or metric threads for tension and compression applications.

Care should be exercised to isolate your ELHS from off-axis loads. The ELHS is a Poisson column design providing low full scale input deflection and superior resolution. Designed specifically to provide high resolution and low deflection. The ELHS can be configured with a variety of options to fine tune the instrument to your application: select from several standard compensated temperature ranges, input voltages, lead lengths or specify entirely unique combinations of these options.

Features

  • Low mass compression style or tension compression with studs
  • Ranges from 1 kN to 50 kN
  • Low noise
  • High reliability

Applications

  • Assembly forces
  • Applications requiring ultra fast response
  • Tool forces
  • Thrust measurements
  • Measurements requiring low sanaor deflection and high resolution
  • Product validation testing

Specifications All values are typical at temperature 20 ±1 °C

Parameter Value

Supply voltage:

15 VDC

Input resistance:

1500 Ω nom.

Output resistance:

500 Ω nom.

Non-repeatability:

±0.25 % FSO

Combined non-linearity and hysteresis:

±0.5 % FSO

Thermal Zero Shift "TZS":

±0.02 % FSO/K

Thermal Sensitivity Shift "TSS":

±0.05 % /K

Operating temperature:

-20 … +80 °C

Compensated temperature:

+20 … +80 °C, see option table for other temperatures

Zero offset at 23 °C:

±10 mV typ.

CE conformance according to

EN 61010-1, EN 50081-1, EN 50082-1

Standard Ranges Overrange Body Style Output FSO

kN

lbf

 

Compression

Tension and Compression

(nom.)

1

200

1.5 x FS

ELHS-B1

ELHS-T1

200 mV

2.5

500

1.5 x FS

ELHS-B1

ELHS-T1

200 mV

5

1k

1.5 x FS

ELHS-B1

ELHS-T1

200 mV

10

2k

1.5 x FS

ELHS-B4

ELHS-T4

200 mV

25

5k

1.5 x FS

ELHS-B4

ELHS-T4

200 mV

50

10k

1.5 x FS

ELHS-B6

ELHS-T6

200 mV

Note:
Type B units: - positive output in compression.
Type T units: - positive output in tension.

Dimensions

Dimensions ELHS type B
ELHS-B1
(1 kN to 5 kN)
ELHS-B4
(10 kN to 25 kN)
ELHS-B6
(50 kN)

A

3 m (10 ft) shielded cable

3 m (10 ft) shielded cable

3 m (10 ft) shielded cable

B

Ø 10 mm (0.39”)

Ø 20 mm (0.78”)

Ø 28 mm (1.1”)

C

3 mm (0.12”)

3 mm (0.12”)

6 mm (0.24”)

D

Ø 3 mm (0.12”)

Ø 3 mm (0.12”)

Ø 5 mm (0.2”)

E

Ø 15 mm (0.59”)

Ø 25 mm (0.98”)

Ø 35 mm (1.38”)

F

15 mm (0.59”)

25 mm (0.98”)

35 mm (1.38”)

G

1 mm (0.04”)

1 mm (0.04”)

1 mm (0.04”)

Dimensions of ELHS type T
ELHS-T1
(1 kN to 5 kN)
ELHS-T4
(10 kN to 25 kN)
ELHM-T6
(50 kN)

A

-T1E: 3/8-24 UNF
-T1M: M10x1.5

-T4E: 5/8-18 UNF
-T4M: M16x2

-T6E: 3/4-16 UNF
-T6M: M20x2.5

B

3 m (10 ft) shielded cable

3 m (10 ft) shielded cable

3 m (10 ft) shielded cable

C

Ø 3 mm (0.12”)

Ø 3 mm (0.12”)

Ø 5 mm (0.2”)

D

3 mm (0.12”)

3 mm (0.12”)

6 mm (0.24”)

E

Ø 15 mm (0.59”)

Ø 25 mm (0.98”)

Ø 35 mm (1.38”)

F

15 mm (0.59”)

25 mm (0.98”)

30 mm (1.18”)

G

15 mm (0.59”)

25 mm (0.98”)

30 mm (1.18”)

H

15 mm (0.59”)

25 mm (0.98”)

30 mm (1.18”)

All dimensions in mm (inch), approx. values. These drawings are for information only and not intended for construction purpose. Please ask for detailed drawings.

Installation

Installation of loadcell ELHS

Wiring

Wiring of loadcell ELHS

Ordering Information

Ordering Information of ELHS
Option Code Description

Compensated Temperature Range

Z0

-40 … +20 °C

 

Z1

-20 … +40 °C

 

Z*

Non-standard

Supply voltage

V00

Replace “00” with excitation between 1 and 10 V.

Special cable length

L00F

Replace “00” with the total cable length in feet.
Specified on units with lbf range.

 

L00M

Replace “00” with the total cable length in meters.
Specified on units with N range.

Connector wired to cable

C

Microtech type male or equivalent (w/o mate)

 

RS

RJ telephone type male (w/o mate)

Calibration

AC

Alternate calibration: units with studs are calibrated
in tension by default. Option AC provides compression
calibration in addition to tension calibration.

Note:
L = lbf; N = Newton.
Metric threaded units must have Newtons range specified. SAE threaded units must have lbf range specified. Metric threaded units must have cable lengths specified in meters. SAE threaded units must have cable lengths specified in inches.